/fs/cache/6b/01/2b/64/e9ff518e644069d49a81e964.jpg

ВАБ-UEТМ®-55-1600

The circuit breaker is designed to protect the equipment of direct current electric trains against short-circuit currents and unacceptable overloads. 

Parameters

Parameters

Norms

WAB-UEТМ®-55-1600/30-L-UHL1

 

WAB-UEТМ ®-55-1600/30-L-U2

1. Main circuit current

DC

2. Polarization

Non-polarized

3.Drive type

Electromagnetic

4. Rated voltage of the main circuit, V

3000

5. Maximum operating voltage, V

4100

6. Rated current at a constant load in time, A

1600

7. Nominal DC voltage of control circuits, V

110

8. Current limits of the setpoint, A

2000-4000

9. Breaking capacity, A

- with inductance of 5-15 mH

- with inductance of 35 mH

 

20000

8000

10. The smallest switchable current, A

30

11. Own opening time, s

0,004

12. Number of trips

100

13. Resource for mechanical wear resistance

      - without maintenance

      - with regular maintenance

50000 cycles

4х50000 cycles

14. Weight of circuit breakers without spare parts, kg, not more

450

215

15. Service life of the circuit breaker, years

40

Write us

Your message has been send succesfully!
logo

Акционерное Общество "Уралэлектротяжмаш"

Yekaterinburg,
Frontovyh brigad, 22
+7 (343) 324-53-00
secretary@uetm.ru